Once the tank wall surface has been properly prepared, stranded wire cables are secured circumferentially to the tank with turn-buckles and pre-tensioned.
|
|

Continuous vertical panels, manufactured to tank height, are hoisted into place. |

Stainless steel fasteners are looped around the cables and positioned between the flanges of adjacent panel sections. Fasteners allow the cables to expand and contract.
|

Installer works from a traveling stage. Scaffolding is not required. |
|

TufSeam panels are easily modified in the field to fit tank irregularities.
|
|

Careful attention is directed to the sealing of the tank appurtenances. The panels are field-fitted tightly to the appurtenances and then caulked with the proper materials.
|
|

Self-propelled tool travels up panel to close the seam and lock the fasteners in place.
|
|

Tufseam's double rolled vertical seam assures a weatherproof joint. |
|

Flashing is attached to the top circumference of the tank and caulked. |
|

Removable inspection ports give easy access to your tank's integrity
|
|

Finished Tanks
|
|