Standard Installation

Once the tank wall surface has been properly prepared, stranded wire cables are secured circumferentially to the tank with turn-buckles and pre-tensioned.

Continuous vertical panels, manufactured to tank height, are hoisted into place.

Stainless steel fasteners are looped around the cables and positioned between the flanges of adjacent panel sections. Fasteners allow the cables to expand and contract.

Installer works from a traveling stage. Scaffolding is not required.

TufSeam panels are easily modified in the field to fit tank irregularities.

Careful attention is directed to the sealing of the tank appurtenances. The panels are field-fitted tightly to the appurtenances and then caulked with the proper materials.

Self-propelled tool travels up panel to close the seam and lock the fasteners in place.

Tufseam's double rolled vertical seam assures a weatherproof joint.

Flashing is attached to the top circumference of the tank and caulked.

Removable inspection ports give easy access to your tank's integrity

Finished Tanks